| Product Name : Veterinary I.V. Catheter | ||
| Product Code : MDH-JWIVC | ||
| Brand : J-CATH | ||
| Trade Term : FOB or Others | ||
| Origin : R.O. Korea | ||
| Certificates : KGMP | ||
| Price : By Reuqest | ||
| MOQ : 1,000pcs / One order | ||
| Instruction Manual | ||
| 1. Prepare the site carefully before venpuncture. | ||
| 2. Make sure that the package and contents are intact and that the expiry date has been exceeded. | ||
| 3. Hold the transparent hub firmly with thumb and index finger and enable a steady grip. This minimizes the risk | ||
| of contamintion by touch. | ||
| 4. Advance the cannula through the skin and puncture the vein. When venepunctured, avoid absolutly that | ||
| the point of cannula penetreates the opposite wall of blood vessel. | ||
| 5. Exact venepuncture is indicated by the entry of blood into the flushback chamber. | ||
| 6. Change grip and hld with thumb and middle finger. Place index finger on the tap on the cannula hub. | ||
| 7. Advance the catheter by pushing on the tab. | ||
| 8. Withdraw the needle completely. Avoid blood spilage by pressing the vein above the catheter tip with a finger. | ||
| 9. Connect the catheter hub to the infusion line. If not for immediate use for the catheter, should be flushed with | ||
| saline or heparinized saline solution before closure. | ||
| 10. Secure the catheter and protect the puncture site. The infusion line should be connected through the hole of | ||
| hub wing. Good fixation is important to prevent mechanical irritation. | ||
| 11. The puncture site should be checked regularly for signs of inflammation. | ||
| Caution for safety | ||
| 1. Users should be fully, aware of instruction manual and caution and cope with the latent dangers concerned with | ||
| use. | ||
| 2. A partially or complelly withdrawn needle from catheter must naver be reinserted into the catheter tubing. | ||
| When reinserted, the sharp of needle damages catheter tubing and cuts it. Therefore, this can bring accident which | ||
| the tubing cut enters into blood vessel. | ||
| 3. If users is pierced by needle withdrawn from catheter inserted to blood vessel, user can be infected with any | ||
| other infectious diseases. | ||
| 4. In case of removing catheter from blood vessel, remove it slowly and carefully without adding strong force | ||
| because of reisk of cut. | ||
| 5. If first venepuncture is failure, the falling catheter must never be used for revenepuncture. | ||
| Discard the falling catheter and use new catheter surely. | ||
| 6. Prohibit absolutely the use of the sharp device same as knife and scissors etc. at the site which catheter is inserted. | ||
| * Sterile : Unless individual package has been opened or damaged. | ||
| * Single use only. | ||
| Specification | ||
| * 14G : 76mm(3") / 102mm(4") / 140mm(5 1/2") | ||
| * 16G : 76mm(3") / 102mm(4") / 140mm(5 1/2") | ||
| * Inner box : 50pcs | ||
| * Carton Box : 200pcs | ||
| * carton size : 4" & 5 1/2" : 608x228x135mm | ||
| 3" : 468x228x135mm | ||